| high speed door 当前位置: Home >>News>>Company News | 
| Frequently Asked Questions about Fast Rolling Doors | 
|   1. The brake slip problem of fast rolling door a. Reason: The compression spring force is reduced. Solution: Replace the spring. b. Reason: The brake pads of the fast rolling door are stained with oil. 
 Solution: Clean with gasoline. 
 2. the troubleshooting of the motor of the fast rolling door does not start, Reason: a.The wire is broken. Solution: Find the connected wire. b.The relay coil is broken or oxidized and contaminated. Solution: Replace the relay or polish the contacts. c The normally closed contact of the limit switch is not open. Solution: Polish the contacts or replace the limit switch. d. The bridge rectifier is broken or the electromagnetic coil is broken, and the brake is stuck. Solution: Replace the bridge rectifier or electromagnetic coil. e. Overheating protection fails. Solution: Replace the overheat protector. f. The running capacitor is damaged. Solution: Replace the running capacitor. g. The continuous running time is too long and the thermal protection is disconnected. 
 Solution: Reduce the motor temperature. 
	  | 
| 文章From:http://www.serangabc.com//te_news_news/2021-10-29/39572.chtml |